Relative Diffuse Reflectance Measurement - Especificações
Diffuse Reflectance Measurement
ISR-603 Integrating Sphere Attachment
This attachment is used for the measurement of diffuse and spealar reflectance. Transmission of liquid and solid samples can also be measured.
Angle of incident light |
0°/8° |
---|---|
Faixa de comprimento de onda |
220 to 2600 nm |
Maximum size of reective sample |
Approx. 100 mm dia. x 15 mm thick |
Integrating sphere |
60 mm I.D. BaSO4 |
Detectores |
PMT, InGaAs, cooled PbS |
Note: For UV-3600Plus series
Note: The optional cuvette attachment is required for transmission measurement of liquid samples.
ISR-240A Integrating Sphere Attachment
Angle of incident light |
0° |
---|---|
Faixa de comprimento de onda |
240 to 800 nm |
Maximum size of reflection sample |
40 mm W x 70 mm H x 10 mm T or |
Cell holder for transmission sample |
with holder for 10 mm square cell (excluding cell), 2 sample plates for BaSO4 standard white board, 2 plates for powder samples |
Note: For UV-3600Plus series
ISR-2200 Integrating Sphere Attachment
Diffuse and spectral reflection can be measured without using special attachments by combining a 0°/8° incident integrating sphere with the S/R exchange function of the spectrophotometer. Since the size of the flux of the reflection measuring unit can be altered, micro samples of with a minimum flux size of 2 x 3 mm can be measured. The flux size of the transmission measuring unit also can be closed down to about 3 x 3 mm.
Angle of incident light |
0°/8° |
---|---|
Faixa de comprimento de onda |
220 to 850 nm |
Maximum size of reflection sample |
70 mm W x 70 mm H x 20 mm T (0° angle of incidence side) |
Cell holder for transmission sample |
with holder for 10 mm square cell (excluding cell), 2 sample plates for BaSO4 standard white board, 2 plates for powder samples |
Note: For UV-3600Plus series
ISR-3100 Integrating Sphere Attachment
Angle of incident light |
0°/8° |
---|---|
Faixa de comprimento de onda |
220 to 2600 nm |
Maximum size of reflection sample |
about 100 mm dia. x 15 mm T |
Cell holder for transmission sample |
with holder for 10 mm square cell (excluding cell), 2 sample plates for BaSO4 standard white board, 2 plates for powder samples |
Note: For UV-3600Plus series
ISR-2600/ISR-2600Plus Integrating Sphere Attachment
Angle of incident light |
0°/8° |
---|---|
Measurement wavelength range |
ISR-2600 220 to 850 nm, ISR-2600Plus 220 to 1400nm |
Maximum size of reflection sample |
70 mm W x 70 mm H x 20 mm T (0° angle of incidence side) |
Note: For UV-3600Plus series
Note: ISR-2600 can be used with UV-2700.
LISR-3100 150mm dia. Integrating Sphere Attachment
This attachment is used to measure the transmission and reflectance spectra of solid samples, such as powder, paper and cloth. Stable measurement is possible regardless of the state of the sample surface.
Angle of incident light |
7° |
---|---|
Faixa de comprimento de onda |
240 to 2400 nm |
Maximum size of reflection sample |
about 150 mm W x 170 mm H x 30 mm T |
Note: For UV-3600Plus series